Clean Room Equipment
BIOSAFETY CABINET
A biosafety cabinet (BSC)—also called a biological safety cabinet or microbiological safety cabinet—is an enclosed, ventilated laboratory workspace for safely working with materials contaminated with (or potentially contaminated with) pathogens requiring a defined biosafety level. Several different types of BSC exist, differentiated by the degree of biocontainment required.
BIOSAFETY CABINET A2
- 30% air exhaust & 70% inner recycle.
- User friendly control software interface, simple operation, LCD screen.
- Preset filter failure and breakdown alarm technology.
- Germany imported asynchronous motor.
- Negative pressure to form an air curtain and box type double isolation between work area and external environment to best protect room side environment.
BIOSAFETY CABINET B2
- 100% air exhaust.
- User friendly control software interface, simple operation, LCD screen.
- Present filter failure and breakdown alarm technology.
- Germany imported asynchronous motor.
- Negative pressure to form an air curtain and box type double isolation between work area and external environment to best protect room side environment.
VERTICAL LAMINAR AIR FLOW
Vertical Laminar Air Flow Unit: we manufacture, supply and export is fabricated using supreme quality materials. The Vertical Laminar Air Flow Unit offered by us is widely demand owing to its high end performance and reliability. Moreover, reasonable price has been fixed for the Vertical Laminar Air Flow Unit.
- High product protection by provision of ISO Class 5 particle free work area.
- Able enough to handle critical process.
- The work area is continuously supplied with positive pressure HEPA filtered vertical air flow.
- Vertical unidirectional airflow peed prevents contamination from operator and environment to work area.
- Made available in powder coated Mild Steel and SS 304 / SS 316/ SS 316L or a combination of both.
- Two Stage filtration.
- EU6 – Pre filter (95% down to 5 micron).
- EU14 – HEPA Filter – Supply (99.999% down to 0.3 micron)
- Dynamically balanced Motor-blower provided with suspension arrangement to minimize the noise level
- SS work table with due reinforcement
- Glass side panels
- Fluorescent Lights with Milky White Diffuser
- Differential Pressure Gauge: 1 No.
- On / Off Switch
- Clean Down Timer with Operation HOLD indicator
- DOP Test Port
- 5/15 Amp Switch Socket for external equipment
- Front doors (hinged/pneumatic cylinder)
- Night Mode Operation.
- SS Air / Gas Cock.
- U. V. Light with Hour Meter.
- Velocity display with alarms (audible and visible).
- Filter blocked alarms (audible and visible)
- Explosion proof electrics for Flame-proof applications
- Audio / Visual alarm for blower tripping with Fault Acknowledgement & Reset Switch
- Photohelic Gauge with Audio / Visual Alarm in lieu of Magnehelic Gauge with High / Low Indicators
- Digital Pressure Gauge in lieu of Magnehelic Gauge
- On Line Velocity Indicator with Audio / Visual Alarm with High / Low Indicators
DYNAMIC PASS BOX
Pass Box is a closed steel box with a double door used for transferring the material from nonsterile door to sterile door inside the clean room. People uses Air showers to pass through into the clean room where material uses pass boxes to get into the clean room. Pass through box is clean room equipment designed in two categories one is a static pass box and the other is a dynamic pass box. Pass boxes provide a controlled environment to the clean room from airborne cross-contamination for a better research environment.
- Cabinet material: Stainless steel/ Powder coated steel
- Internal material: Sand polished stainless steel
- Efficiency: 99.995%@0.3μm
- Power supply: 220V/110V
- Blow time: 10s/15s/30s/999s
- Interlock: Electromagnetic
- Optional: UV lamp
HORIZONTAL LAMINAR AIR FLOW
FUME HOOD
- GMP Standard
- Competitive Price
- 304 Stainless Steel
- Adjustable Air Volume
- Good After-sale Service Performance
FRESH AIR UNIT
- Multi-stage filtration box
- Good sealing performance
- Connect with duct and configure the professional filters
- Optional filtration stages: pre filter + medium filter / pre filter + medium filter + HEPA filter / pre filter + HEPA filter etc.
AIR SHOWER
Air shower is a necessary passage for person or goods entering into the clean room in order to minimize the amount of particulate contaminants. Personnel move through the air shower while particulate contaminants are blew off by the clean high velocity. The high air velocity of 25m/s ensures the efficiency. Contaminated air is then taken in through the base of the unit, filtered and re-circulated into the chamber.
- Blow way: Single blow/Double blow/Three blow/surrounded blow/Vertical blow
- SS nozzle diameter: ø25mm
- Material: stainless steel 304 material
- Controller: Electronic control panel / PLC
- Power supply: 220V/380V
HEPA BOX
HEPA box is a terminal filtration device with side and vertical configured air supply. It consists of a static pressure box, HEPA filter and diffused hole plate. A range of finishes are available, including cold rolled steel, stainless steel 201 / 304, and powder coated steel for user choice.
It is installed at the same level of the ceiling where a HEPA filter is fixed inside the box to produce the required cleanliness in its specified classification. It creates turbulent flow to ensure a good mixture of dust-free air in the environment.
- Cabinet material: Cold rolled steel with powder coated / Stainless steel
- Air intake position: At side / at top
- Flange: Square/ Circle
- Optional flange port / flange / damper position: at side / at top
- Optional filter type: HEPA mini-pleat filter / HEPA separator filter.
STATIC PASS BOX
Pass Box is a closed steel box with a double door used for transferring the material from nonsterile door to sterile door inside the clean room. People uses Air showers to pass through into the clean room where material uses pass boxes to get into the clean room. Pass through box is clean room equipment designed in two categories one is a static pass box and the other is a dynamic pass box. Pass boxes provide a controlled environment to the clean room from airborne cross-contamination for a better research environment.
- Cabinet material: Cold rolled steel with powder coated / Stainless steel
- Internal material: Sand light stainless steel
- Thickness of material: 1.0mm / 1.2mm
- Power supply of electromagnetic interlock / UV lamp: 220V/50Hz
FAN FILTER UNIT
A fan filter unit (FFU) is a type of motorized air filtering equipment. It is used to supply purified air to cleanrooms, laboratories, medical facilities or microenvironments by removing harmful airborne particles from recirculating air. The units are installed within the system’s ceiling or floor grid. Large cleanrooms require a proportionally large number of FFUs, which in some cases may range from several hundred to several thousand. Units often contain their own pre-filter, HEPA filter and internally controllable fan air distribution.
AstroFan FFU – AC is a low energy consumption HEPA module
- This HEPA module’s backward curved motorized impeller uses minimal electricity.
- Available with variable speed controller.
- AstroFan FFU – AC generates low noise.
- It is a sturdy construction.
SAMPLING & DISPENSING BOOTH (RLAF)
The Weighing Booth, also known as Negative Pressure Room is a dedicated local decontamination unit that conforms to the latest version of GMP for the production of sterile formulation. It provides a vertical unidirectional airflow with a fraction (80% – 90%) of clean air circulating through the working area, and another fraction (10% – 20%) discharged to the vicinity of the working area to provide negative pressure to prevent dust spill and cross-contamination in the work area, in order to ensure a high degree of cleanliness of the working environment.
- Cabinet material: 304 stainless steel wire drawing board.
- Control panel: PLC intelligent control.
- Air velocity: 0.35~0.65m/s, automatically adjusted.
- Air supply: vertical air flow.
- Clean class: ISO5 (static 100).
PERFORATED SHEET
- Suitable for supply and return for ceiling/riser installations.
- Efficient draftless air distribution for all types of ceilings.
- Built in pattern controllers provide 1, 2, 3, 4-way flow.
MATERIAL
Aluminium / Galvanised Steel / Stainless Steel.
FINISH
Powder coated, natural anodized, colour anodized, primer coated, emulsion painted or buff finish.
RETURN RAISER FILTER
Return vent filters operate behind the openings of the return vents in your house. They support HVAC system components by removing solid contaminants from the air. As the air is pulled into the return vents, the filter catches contaminants before entering the air stream in the ductwork.
MAGNEHELIC GAUGE
The Magnehelic gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, and pressure drop across orifice plate.
MAGNEHELIC GAUGE BOX
Magnehelic Gauge SS BOX SS-304 stainless steel hinged box has a polished satin finish. This box has a hinged door with a face cut-out to accept a Dwyer magnehelic pressure guage. Box comes complete with holes to accept pressure differential sensors.
PRESSURE MODULE (POSITIVE / NEGATIVE)
MODULAR CLEAN BOOTH
- Moveable self-clean equipment
- Optional back-up source to increase range of movement
- High quality fan motor, low noise and long life span
LAMINAR AIR FLOW CEILING
- Cabinet material: Cold rolled steel with powder coated / Stainless steel.
- Efficiency: 99.99%@0.3μm
- Advantage: Applying leading resistance drain layer technology which allows reasonable airflow distribution inside clean room, effectively guarantee the indoor cleanliness.